Please use this identifier to cite or link to this item:
https://physrep.ff.bg.ac.rs/handle/123456789/114
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Skerovic, Vladan | en |
dc.contributor.author | Zarubica, Veljko | en |
dc.contributor.author | Kasalica, Bećko | en |
dc.contributor.author | Stojadinović, Stevan | en |
dc.contributor.author | Belča, Ivan | en |
dc.date.accessioned | 2022-06-30T15:20:56Z | - |
dc.date.available | 2022-06-30T15:20:56Z | - |
dc.date.issued | 2009-01-01 | en |
dc.identifier.issn | 0003-2719 | en |
dc.identifier.uri | https://physrep.ff.bg.ac.rs/handle/123456789/114 | - |
dc.description.abstract | Medical diagnostics and therapy use an extensive amount of electronics, optoelectronics, and laser devices. For their reliable functioning, calibration is unavoidable. Biochemical analyzers, which work on principles of absorptional spectrophotometry, became most widely present in medical biochemical laboratories. Construction of these devices is such, that in most cases, it does not allow calibration by usual methods, using neutral density (ND) filters as standards. For this reason, it was necessary to create a solution that could be used as a mean of comparison or even as a standard solution for methods of calibration of biochemical analyzers. In this article, the metrological characterization of solutions that are developed is presented, and the measuring uncertainty (ISO 1993) of methods used for calibration is estimated. The method that is developed provides metrological traceability to the primary spectrophotometric standard. With this method, metrological assurance in the field of the spectrophotometry in medical laboratories is completed. Copyright © Taylor & Francis Group, LLC. | en |
dc.relation.ispartof | Analytical Letters | en |
dc.subject | Biochemical analyzers | en |
dc.subject | Calibration | en |
dc.subject | Measurement uncertainty | en |
dc.subject | Metrological | en |
dc.subject | Spectrophotometry | en |
dc.subject | Tracability | en |
dc.title | Metrological assurance of biodevices: The new method of calibration of biochemical analyzers | en |
dc.type | Article | en |
dc.identifier.doi | 10.1080/00032710802507448 | en |
dc.identifier.scopus | 2-s2.0-61649128079 | en |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/61649128079 | en |
dc.relation.issue | 2 | en |
dc.relation.volume | 42 | en |
dc.relation.firstpage | 330 | en |
dc.relation.lastpage | 338 | en |
item.grantfulltext | none | - |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
crisitem.author.orcid | 0000-0002-8300-6234 | - |
crisitem.author.orcid | 0000-0002-6589-6296 | - |
crisitem.author.orcid | 0000-0001-6124-5333 | - |
Appears in Collections: | Journal Article |
SCOPUSTM
Citations
1
checked on Oct 30, 2024
Page view(s)
16
checked on Nov 5, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.