Please use this identifier to cite or link to this item: https://physrep.ff.bg.ac.rs/handle/123456789/1201
DC FieldValueLanguage
dc.contributor.authorStojadinović, Stevanen_US
dc.contributor.authorLow, D Aen_US
dc.contributor.authorHope, A Jen_US
dc.contributor.authorVićić, Milošen_US
dc.contributor.authorDeasy, J Oen_US
dc.contributor.authorCui, Jen_US
dc.contributor.authorKhullar, Den_US
dc.contributor.authorParikh, P Jen_US
dc.contributor.authorMalinowski, K Ten_US
dc.contributor.authorIzaguirre, E Wen_US
dc.contributor.authorMutic, Sen_US
dc.contributor.authorGrigsby, P Wen_US
dc.date.accessioned2022-07-12T18:35:38Z-
dc.date.available2022-07-12T18:35:38Z-
dc.date.issued2007-12-
dc.identifier.issn0094-2405en
dc.identifier.urihttps://physrep.ff.bg.ac.rs/handle/123456789/1201-
dc.description.abstractA novel small animal conformal radiation therapy system has been designed and prototyped: MicroRT. The microRT system integrates multimodality imaging, radiation treatment planning, and conformal radiation therapy that utilizes a clinical 192Ir isotope high dose rate source as the radiation source (teletherapy). A multiparameter dose calculation algorithm based on Monte Carlo dose distribution simulations is used to efficiently and accurately calculate doses for treatment planning purposes. A series of precisely machined tungsten collimators mounted onto a cylindrical collimator assembly is used to provide the radiation beam portals. The current design allows a source-to-target distance range of 1-8 cm at four beam angles: 0 degrees (beam oriented down), 90 degrees, 180 degrees, and 270 degrees. The animal is anesthetized and placed in an immobilization device with built-in fiducial markers and scanned using a computed tomography, magnetic resonance, or positron emission tomography scanner prior to irradiation. Treatment plans using up to four beam orientations are created utilizing a custom treatment planning system-microRTP. A three-axis computer-controlled stage that supports and accurately positions the animals is programmed to place the animal relative to the radiation beams according to the microRTP plan. The microRT system positioning accuracy was found to be submillimeter. The radiation source is guided through one of four catheter channels and placed in line with the tungsten collimators to deliver the conformal radiation treatment. The microRT hardware specifications, the accuracy of the treatment planning and positioning systems, and some typical procedures for radiobiological experiments that can be performed with the microRT device are presented.en
dc.language.isoenen
dc.relation.ispartofMedical physicsen
dc.subjectMicroradiation therapyen
dc.subjectMicroRTen
dc.subjectMicroRTPen
dc.subjectSmall animal irradiationen
dc.subject.meshIridium Radioisotopesen
dc.subject.meshRadioisotope Teletherapyen
dc.subject.meshRadiotherapy, Conformalen
dc.titleMicroRT-small animal conformal irradiatoren_US
dc.typeJournal Articleen_US
dc.identifier.doi10.1118/1.2799887-
dc.identifier.pmid18196798-
dc.identifier.scopus2-s2.0-36649037794-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/36649037794-
dc.relation.issue12en
dc.relation.volume34en
dc.relation.firstpage4706-16en
dc.relation.lastpage4716en
item.openairetypeJournal Article-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextnone-
Appears in Collections:Journal Article
Show simple item record

SCOPUSTM   
Citations

91
checked on Nov 19, 2024

Page view(s)

31
checked on Nov 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.