Please use this identifier to cite or link to this item: https://physrep.ff.bg.ac.rs/handle/123456789/1204
DC FieldValueLanguage
dc.contributor.authorEl Naqa, Issamen_US
dc.contributor.authorLow, Daniel Aen_US
dc.contributor.authorBradley, Jeffrey Den_US
dc.contributor.authorVićić, Milošen_US
dc.contributor.authorDeasy, Joseph Oen_US
dc.date.accessioned2022-07-12T18:35:38Z-
dc.date.available2022-07-12T18:35:38Z-
dc.date.issued2006-10-
dc.identifier.issn0094-2405en
dc.identifier.urihttps://physrep.ff.bg.ac.rs/handle/123456789/1204-
dc.description.abstractIn FDG-PET imaging of thoracic tumors, blurring due to breathing motion often significantly degrades the quality of the observed image, which then obscures the tumor boundary. We demonstrate a deblurring technique that combines patient-specific motion estimates of tissue trajectories with image deconvolution techniques, thereby partially eliminating breathing-motion induced artifacts. Two data sets were used to evaluate the methodology including mobile phantoms and clinical images. The clinical images consist of PET/CT co-registered images of patients diagnosed with lung cancer. A breathing motion model was used to locally estimate the location-dependent tissue location probability function (TLP) due to breathing. The deconvolution process is carried by an expectation-maximization (EM) iterative algorithm using the motion-based TLP. Several methods were used to improve the robustness of the deblurring process by mitigating noise amplification and compensating for motion estimate uncertainties. The mobile phantom study with controlled settings demonstrated significant reduction in underestimation error of concentration in high activity case without significant superiority between the different applied methods. In case of medium activity concentration (moderate noise levels), less improvement was reported (10%-15% reduction in underestimation error relative to 15%-20% reduction in high concentration). Residual denoising using wavelets offered the best performance for this case. In the clinical data case, the image spatial resolution was significantly improved, especially in the direction of greatest motion (cranio-caudal). The EM algorithm converged within 15 and 5 iterations in the large and small tumor cases, respectively. A compromise between a figure-of-merit and entropy minimization was suggested as a stopping criterion. Regularization techniques such as wavelets and Bayesian methods provided further refinement by suppressing noise amplification. Our initial results show that the proposed method provides a feasible framework for improving PET thoracic images, without the need for gated/4-D PET imaging, when 4-D CT is available to estimate tumor motion.en
dc.language.isoenen
dc.relation.ispartofMedical physicsen
dc.subjectBreathing motionen
dc.subjectDeconvolutionen
dc.subjectPositron emission tomographyen
dc.subject.meshLung Neoplasmsen
dc.subject.meshMotionen
dc.subject.meshPositron-Emission Tomographyen
dc.subject.meshRadiography, Thoracicen
dc.subject.meshRespirationen
dc.titleDeblurring of breathing motion artifacts in thoracic PET images by deconvolution methodsen_US
dc.typeJournal Articleen_US
dc.identifier.doi10.1118/1.2336500-
dc.identifier.pmid17089825-
dc.identifier.scopus2-s2.0-33749410633-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/33749410633-
dc.relation.issue10en
dc.relation.volume33en
dc.relation.firstpage3587-600en
dc.relation.lastpage3600en
item.openairetypeJournal Article-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextnone-
Appears in Collections:Journal Article
Show simple item record

SCOPUSTM   
Citations

59
checked on Nov 20, 2024

Page view(s)

25
checked on Nov 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.