Please use this identifier to cite or link to this item:
https://physrep.ff.bg.ac.rs/handle/123456789/594
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Popović, Dušan | en |
dc.contributor.author | Milosavljević, Vladimir | en |
dc.contributor.author | Daniels, S. | en |
dc.date.accessioned | 2022-07-12T16:01:40Z | - |
dc.date.available | 2022-07-12T16:01:40Z | - |
dc.date.issued | 2007-12-07 | en |
dc.identifier.issn | 0021-8979 | en |
dc.identifier.uri | https://physrep.ff.bg.ac.rs/handle/123456789/594 | - |
dc.description.abstract | This paper presents a method for precise measurement of atomic and molecular nitrogen in an oxygen-nitrogen dc plasma. This is achieved by monitoring the intensities of the atomic nitrogen spectral line at 821.6 nm and the molecular nitrogen bandhead at 337.1 nm, relative to the atomic oxygen spectral line at 844.7 nm. Oxygen is one of the most frequently used gases for surface chemical treatment, including deposition and etching, therefore the ability to measure and control the process and chemical composition of the process is essential. To validate this oxygen actimometry method for N2 -x O2 (where x varies from 0 to 1) dc plasmas, threshold tests have been performed with Ar actinometry. The optical measurements have been performed using two methods. The first approach uses a USB2000 fiber optic spectrometer, calibrated with a Gigahertz-Optik BN-0102-1 reference standard source, to record the desired spectral lines. The second approach uses narrow bandwidth optical filters (∼0.7-0.07 nm) with central wavelengths of 821.6, 337.1, and 844.69 nm and photodiodes to detect the emission intensity, also calibrated with the same standard source. Optical data are collected for a range of experimental conditions in a flowing glow discharge of N2 -x O2 mixture. The maximum dc voltage is 2.2 kV and maximum chamber pressure is 266 Pa. Data from both optical methods are compared and used to interpret the relative atomic and molecular nitrogen concentrations under various operating conditions. © 2007 American Institute of Physics. | en |
dc.relation.ispartof | Journal of Applied Physics | en |
dc.title | Practical sensor for nitrogen in direct current glow discharges | en |
dc.type | Article | en |
dc.identifier.doi | 10.1063/1.2816254 | en |
dc.identifier.scopus | 2-s2.0-36649006880 | en |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/36649006880 | en |
dc.relation.issue | 10 | en |
dc.relation.volume | 102 | en |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | none | - |
crisitem.author.orcid | 0000-0002-7805-5189 | - |
Appears in Collections: | Journal Article |
SCOPUSTM
Citations
7
checked on Nov 21, 2024
Page view(s)
22
checked on Nov 22, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.