Please use this identifier to cite or link to this item: https://physrep.ff.bg.ac.rs/handle/123456789/880
Title: Performance of the CMS ECAL safety system for Super Modules SM0 and SM1
Authors: Milenović, Predrag 
Puzović, Jovan 
Jovanovic, D.
Maletic, D.
Dissertori, G.
Adzic, P.
Keywords: CMS;Detector control;Electromagnetic calorimetry;LHC
Issue Date: 1-Dec-2005
Journal: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Abstract: 
A prototype of the safety system for the electromagnetic calorimeter (ECAL) of the CMS detector at LHC has been implemented and tested in Super Modules SM0 and SM1 during the ECAL test-beam campaign in summer 2003. The aim was to examine the system performance thoroughly and to resolve several open issues regarding the final system design. The performed tests mainly focused on the readout system performance, its calibration and noise problems. Furthermore, irradiation tests of the readout electronics components with a 64 MeV proton beam up to an equivalent cumulative dose of 200 kGy and 3.2×10 14 neutron cm -2 have been performed at the Paul Scherrer Institute in spring 2004. The results of all these tests are very promising, leading to the conclusion that the tested prototype offers an excellent basis for the development of the safety system for the entire CMS ECAL. © 2005 Elsevier B.V. All rights reserved.
URI: https://physrep.ff.bg.ac.rs/handle/123456789/880
ISSN: 0168-9002
DOI: 10.1016/j.nima.2005.08.028
Appears in Collections:Journal Article

Show full item record

SCOPUSTM   
Citations

6
checked on Oct 29, 2024

Page view(s)

17
checked on Nov 4, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.