Please use this identifier to cite or link to this item: https://physrep.ff.bg.ac.rs/handle/123456789/438
Title: Pulsed corona driven by a compact repetitive Marx generator
Authors: Sretenovic, Goran B.
Obradović, Bratislav 
Kovačević, Vesna
Kuraica, Milorad
Issue Date: 1-Jan-2010
Journal: HAKONE 2010 - 12th International Symposium on High Pressure Low Temperature Plasma Chemistry
Abstract: 
As a part of a pulsed corona system for pollution control applications, Marx type pulse generator was constructed and tested. It consists of ten capacitor banks which can be connected on different ways to give required voltage and energy and it is able to produce up to 200 kV and 15 J pulses with a respectable repetition rate. For this work we used three and four stages, 40-50 kV generator which gives 4 J per pulse and repetition rate up to 100 pps, according to our laboratory plasma reactor configuration. The generator delivers pulses to the wire-plate reactor with the 40 ns risetime and FWHM of 200 ns. The pulse power system may be used with or without DC bias, with no needs for additional power supply. This arrangement has been tested through the measurement of ozone generation. Finally, the whole system has been used for NO treatment in the laboratory conditions.
URI: https://physrep.ff.bg.ac.rs/handle/123456789/438
ISBN: 9788089186723
Appears in Collections:Conference paper

Show full item record

Page view(s)

18
checked on Nov 21, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.